Dumps Box (DumpsBox) offers up-to-date practice exam questions for CDCS certification exam which are developed and validated by EXIN subject domain experts certified in Exin CDCS . These practice questions are update regularly as we keep an eye on any recent changes in CDCS syllabus, and when there is update our team quickly adjusts the questions. This commitment to providing the best quality exam prep material to certification aspirants is what makes DumpsBox.com the best certification exam prep website. On top of that, our strong, yet strictly moderated, community based feedback keeps the content clean and current. Each question has helpful community discussion that provides it extra perspective and introduces helpful resources for better exam preparation. This also saves students from other outdated practice questions or illicit exam dumps that can have adverse affects on career. Browse through our Exin CDCS exam questions and pass your exam on first try.
What mainly affects the cooling capacity of a raised floor tile?
Select one option, then reveal solution.
Question No. 2
What is a potential disadvantage of using a hypoxic-based fire suppression system as a fire extinguishing system?
Select one option, then reveal solution.
Question No. 3
The location of a data center is just above the Arctic Circle (North Pole). The outside air temperature is never above 21°C/70°F. Taking energy efficiency as the highest priority, which cooling system should you recommend?
Select one option, then reveal solution.
Question No. 4
A new network storage device in a non-standard size rack of approximately 600 kg/1,300 lbs is going to be installed in the data center. Are new floor loading calculations required?
Select one option, then reveal solution.
Question No. 5
When installing a raised floor, can we use a spirit level bar to level the floor?
Select one option, then reveal solution.
Question No. 6
The computer room has high levels of H2S gas contamination. What is the best option to resolve this issue?
Select one option, then reveal solution.
Question No. 7
The air intake of the mission-critical server at the top of the rack is measuring 25 °C/77 °F. Is this acceptable?
Select one option, then reveal solution.
Question No. 8
From the options indicated, what is the correct starting point for the raised floor installation?
Select one option, then reveal solution.
Question No. 9
A data center is located in an area where the demand for power is higher than the utility power company is able to deliver. This results in frequent power outages and, therefore, power shedding (scheduled/controlled power shutdown for areas) is frequently applied. The mains power is more than 650 hours/year not available. What type of generators should be installed?
Select one option, then reveal solution.
Question No. 10
What is the minimum requirement for the power feeds to the building for a Rated-3 data center based on the ANSI/TIA-942 standard?
Select one option, then reveal solution.
Question No. 11
A data center scores Rated-3 in mechanical, Rated-4 in electrical, and Rated-2 in architectural. What is the overall Rating of this data center when the Rating is based on the ANSI/TIA-942?
Select one option, then reveal solution.
Question No. 12
The temperature in the computer room is being increased from 18°C/64°F to 27°C/81°F. What is the impact, if any, on the amount of gas required to suppress a fire assuming the gas is a Halocarbon?
Select one option, then reveal solution.
Question No. 13
Which formula is correct?
Select one option, then reveal solution.
Question No. 14
You are working on the design of a new facility. The electrical riser of the building with high current power is located close to the area where sensitive IT equipment in the computer room will be located. What should you recommend to reduce the amount of EMF coming from the electrical riser?
Select one option, then reveal solution.
Question No. 15
The humidity in the computer room has changed from about 50% down to 35% Relative Humidity (RH). What influence does this have on Electrostatic Discharge (ESD)?